Sunday, 27 August 2023

Coe and compatibility




From time to time you will see the statement:

“CoE is the determinant of compatibility”

This is Not True!  

I wish I could come up with something simple to counteract this CoE fallacy, but glass is complicated and I can’t think of a snappy phrase to help.  To understand why the statement above is false, some background on what CoE does mean and what range of temperature it applies to is important.

The coefficient of expansion can be a measure of either linear or volumetric expansion.  It is most often conducted over the range of 20°C to 300°C.  The result is expressed as an average over this range.  If there are variations in rates of expansion, they are absorbed in this coefficient, ie., average.  The measure is of the part of one metre the material expands for each degree Celsius increase in temperature.  In the glass community this coefficient is expressed as two digits such as 83 which represents the expansion of glass by 0.0000083 of a metre for each degree Celsius change in the measured temperature range.

Note the temperature range over which this is measured – up to 300°C.  This coefficient works well for crystalline solids, but not for glass.  Amorphous solids do not have linear expansion rates throughout the working range of temperatures. Room temperature to 300°C is not a critical temperature range for glass.  After all, many of us turn the kiln off around 370°C.  This means that the CoE measured up to 300°C is not really relevant to us, as we have discovered that the expansion rates for 6mm or less thick glass are not critical below 370°C.


Annealing range
The CoEs at annealing temperatures – the critical range for glass -  are in the 400 to 500 range.  It is in the annealing range – generally about 45°C above and below the annealing point of the glass – that CoE is most important.  The annealing point is above the now popular, but lower, annealing soak temperature. This is where the glass is soaked to obtain a temperature with a differential of no more that 5°C throughout the glass.  The practice has become to do this temperature equalisation at the lower portion of the annealing range.  Often this is only 10°C above the lower boundary of the annealing range. This gives a shorter cool and increases the density of the glass. Do not confuse annealing point with the annealing soak. They are not the same.

Critical temperature range for CoE
The Coefficient of Expansion is more important at the glass transition point. This is the temperature at which the molten material becomes a slightly flexible solid. The CoE and the viscosity interact in this range.  It is critical, as the opposing forces of viscosity and CoE must balance.  The CoE is adjusted by the manufacturer to create this balance.  It shows that CoE is dependent on the viscosity of the glass.  And the characteristics of each colour must also match all the other glass in the range of tested compatible fusing glass. This is not a simple thing to do.  If it were, there would be lots of companies doing it.

Experience of moving to a single CoE for fusing glass
The Bullseye experience of attempting to achieve compatibility across a range of glass in the early days of making fusing compatible glass showed that less compatibility was experienced when the colours had matching CoEs. Lani Macgreggor describes this experience well in this blog, “Eclipse of the Fun”

An expert’s explanation
A Bullseye article by Dan Schwoerer - possibly the major expert on making compatible glass - on achieving compatibility through compensating differences is the key to understanding the balancing of CoE with the viscosity.  It is on the Bullseye site as Tech Note #3.

There is a more impassioned description of matters relating to compatibility in five linked blogs by Lani Macgregor in the To BE or not BE blog.


Manufacturing to a range of CoE
Spectrum long ago stated that the CoE of their glass ranges up to 10 points  to achieve a compatible range of fusing glass.  This is probably true for every manufacturer of fusing compatible glass. 


Why CoE is NOT the determinant of fusing compatible glass
The things that mean CoE cannot be the determinant of compatible glass are:
  • ·        The coefficient is for an inappropriate temperature range for glass.
  • ·        The critical temperatures for expansion are in the annealing range, for which there are no widely published figures.
  • ·        The expansion rates need to be adjusted to match the viscosity in this annealing range.
  • ·        A major manufacturer has indicated their glass, known by the CoE of its fusing standard glass, has a 10-point range of CoEs within their fusing range.



It is not true that CoE is a determinant of compatibility.

CoE is an inappropriate number to indicate compatibility.  It does not guarantee compatibility.  It is a suspiciously accurate number leading people to erroneously believe any glass labelled with a given number will be compatible with any other with the same number. 


Other blog posts on CoE:
CoE does not determine critical temperatures: 

Demonstration that CoE does not determine annealing or fusing temperatures:

Note on the physical changes at annealing

Absence of any correlation between specific gravity and CoE:

No comments:

Post a Comment